Ductile Iron Lift Check Valve>
FIG F69D00
Ductile Iron Lift Check ValveJIS-10K
Parts and materials list | |
Part | Material |
Body | FCD 45 |
Bonnet | FCD 45 |
Disc | SUS 410 |
Body seat ring | SUS 410 |
Connecting nut | FCD 45 |
Gasket | Graphite |
Dimension Unit : mm
1/2 | 3/4 | 1 | 1-1/4 | 1-1/2 | 2 | |
Size | 15 | 20 | 25 | 32 | 40 | 50 |
L | 108 | 117 | 127 | 140 | 165 | 203 |
H | 46.8 | 50.2 | 60.8 | 69.7 | 78.5 | 90.1 |
D | 95 | 100 | 125 | 135 | 140 | 155 |
|
FIG 69D00
Ductile Iron Lift Check ValveKGMC-16K
Parts and materials list | |
Part | Material |
Body | FCD 45 |
Bonnet | FCD 45 |
Disc | SUS 410 |
Body seat ring | SUS 410 |
Dimension Unit : mm
3/8 | 1/2 | 3/4 | 1 | 1-1/4 | 1-1/2 | 2 | |
Size | 10 | 15 | 20 | 25 | 32 | 40 | 50 |
L | 65 | 65 | 80 | 90 | 105 | 120 | 140 |
H | 37 | 37 | 48 | 52 | 64 | 74 | 83 |
* All important parts are adopted of stainless steel material.
* Ductile material is adopted for packing in order to be utilized in the place of high temperature with guaranty of leakage-proof.
Working pressure marking = 16kg/cm2* Ductile material is adopted for packing in order to be utilized in the place of high temperature with guaranty of leakage-proof.
Non-shock water under 120oC = 14kgf/cm2
Steam, Air, Oil, Pulse stream under 220oC = 10kgf/cm2
Hydrostatic test pressure
Shell = 20kgf/cm2
Seat = 15kgf/cm2